Files
Zcu111ResmReceiver/docs/pl_rx_subsystem.md

2.5 KiB

📡 PL Rx Subsystem (Channelizer)

🏠 Project Home


Overview

The Rx subsystem implements a polyphase filter bank (PFB) channelizer followed by FFT processing, a bypass path, and a multi-frame capture pipeline.

It converts wideband ADC input into frequency-domain channels (or raw samples via bypass) and streams the result to the PS.


Architecture

Channelizer Path (default)

ADC

PFB Channelizer (Decimation + Filtering)

FFT (512 bins)

Capture (frame control)

AXI4-Stream (128-bit, 4 samples/clock)

DMA


Bypass Path (Debug / Raw Data)

ADC

Bypass Path

Capture (frame control)

AXI4-Stream (128-bit, 4 samples/clock)

DMA


Capture Pipeline

  • Multi-frame acquisition (configurable nFrames)
  • Frame size: 512 samples
  • Supports asynchronous capture start (not frame-aligned)
  • TLAST asserted at frame boundaries

Behavior

  • First frame may be partial
  • Frames may contain ≤ 2 frame indices (expected)
  • DPW spans nFrames frames but covers nFrames + 1 frame regions

Processing Chain (Channelizer Mode)

ADC Input

  • Sampling rate: 4096 MSPS
  • Data type: fixdt(1,16,15) (Q1.15)

PFB Channelizer

  • Decimation: 8
  • Effective bandwidth: 512 MHz

FFT

  • Size: 512
  • Produces frequency bins

Capture

  • Defines frame boundaries (512 samples)
  • Generates TLAST

Numeric Format and Scaling

System Standardization

  • End-to-end Q1.15 (fixdt(1,16,15))

Channelizer Output Scaling

  • Native: sFix25_En23
  • Quantized to: fixdt(1,16,15) (round + saturate)

Data Packing (Updated)

  • 4 samples per clock
  • Each sample: complex (16-bit real + 16-bit imag)
  • Packed into 128-bit AXI4-Stream word

Benefits:

  • Matches datapath parallelism
  • Efficient DMA transfers
  • Eliminates need for serializer stage

AXI4-Stream Output

  • Width: 128 bits
  • Contains 4 complex samples per cycle
  • TLAST = frame boundary

Debug / Validation Features

A counter-based debug mode is implemented:

  • Real part → sample counter (0..511)
  • Imag part → frame index

Used to validate:

  • Sample continuity
  • Frame boundaries
  • DMA ordering and integrity

Key Characteristics

  • Fully streaming pipeline
  • Deterministic latency
  • High throughput (4 samples/clock)
  • Dual-mode operation (channelizer / bypass)
  • Validated up to nFrames = 1024