📡 PL Rx Subsystem (Channelizer)

🏠 Project Home


Overview

The Rx subsystem implements a polyphase filter bank (PFB) channelizer followed by FFT processing.

It converts wideband ADC input into frequency-domain channels and streams the result to the PS.

A bypass path is also available for raw data inspection and debugging.


Architecture

Channelizer Path (default)

ADC ↓ PFB Channelizer (Decimation + Filtering) ↓ FFT (512 bins) ↓ FFT Capture ↓ FIFO Serializer (4 → 1) ↓ AXI4-Stream ↓ DMA


Bypass Path (Debug / Raw Data)

ADC ↓ Bypass Path ↓ FIFO / Serializer ↓ AXI4-Stream ↓ DMA


Bypass Functionality

The bypass allows direct observation of the input signal without channelization.

Purpose

  • Debugging and validation
  • Access to raw ADC-domain data
  • Comparison with channelized output
  • Verification of downstream processing

Behavior

  • Input data is routed directly to output
  • No filtering or FFT applied
  • Maintains same output interface (AXI4-Stream)

Selection Mechanism

A selector signal chooses between:

  • Channelizer output (normal operation)
  • Bypass output (raw data)

Implementation typically uses:

  • Parallel paths
  • Output switching logic

Processing Chain (Channelizer Mode)

ADC Input

  • Sampling rate: 4096 MSPS

PFB Channelizer

  • Decimation: 8
  • Effective bandwidth: 512 MHz

FFT

  • Size: 512
  • Produces frequency bins

FFT Capture

  • Controls frame boundaries

FIFO Serializer

  • Converts parallel streams into single stream

AXI4-Stream Output

  • Data type: uint64
  • Packed real/imag
  • TLAST = frame boundary

Data Format

  • Frame size: 512 samples
  • Complex values packed into uint64

Key Characteristics

  • Fully streaming pipeline
  • High throughput
  • Deterministic latency
  • Supports dual-mode operation (channelizer / bypass)